XR3/XR6
Frequency Change
Procedure
IS07012
Issue 1.0 ................10 September 2007
Nautel Limited
10089 Peggy's Cove Road,
Hackett's Cove, NS, Canada B3Z 3J4
T.877 6 nautel (628835) or +1.902.823.2233
F.+1.902.823.3183 info@nautel.com
U.S. customers please contact:
Nautel Inc.
201 Target Industrial Circle, Bangor ME 04401
T.877 6 nautel (628835) or +1.207.947.8200
F.+1.207.947.3693 info@nautel.com
www.nautel.com
© Copyright 2007 NAUTEL. All rights reserved.
Przeglądanie stron 0
1 2 3 4 5 6 ... 10 11

Podsumowanie treści

Strona 1 - XR3/XR6

XR3/XR6 Frequency Change Procedure IS07012 Issue 1.0 ...10 September 2007 Nautel Limited 10089 Peggy's Cove Road, Hackett&a

Strona 3 - INFORMATION SHEET

XR3/XR6 Frequency Change Procedure Page 1 of 1 IS07012 (APPENDIX A) Issue 1.0

Strona 5 - IS07012 Issue 1.0

XR3/XR6 Frequency Change Procedure Page 1 of 7 IS07012 Issue 1.0 IS07012 – XR3/XR6 Frequency Change Procedure INFORMATION SHEET 1 INTRODUCTION Th

Strona 6 - Issue 1.0 IS07012

Page 2 of 7 XR3/XR6 Frequency Change Procedure Issue 1.0 IS07012 2 INSTRUCTIONS The frequency change procedure comprises four main steps: • RF

Strona 7

XR3/XR6 Frequency Change Procedure Page 3 of 7 IS07012 Issue 1.0 (a) Locate the transmitter configuration sheets that were included with the Proo

Strona 8

Page 4 of 7 XR3/XR6 Frequency Change Procedure Issue 1.0 IS07012 (e) Install the capacitors in each bank using hardware from the frequency change

Strona 9

XR3/XR6 Frequency Change Procedure Page 5 of 7 IS07012 Issue 1.0 Figure 5: RF Power Module Tuning (TP14 and TP15) (f) Follow the procedure in th

Strona 10

Page 6 of 7 XR3/XR6 Frequency Change Procedure Issue 1.0 IS07012 (c) While monitoring the RF current and voltage, ensure that the RF current lags

Strona 11

XR3/XR6 Frequency Change Procedure Page 7 of 7 IS07012 Issue 1.0 2.4.4 FINE-TUNE RF FILTER INPUT IMPEDANCE Fine tune the RF filter input impedance